Delivering the Sensitivity of Film at an Economical Price

Azure 280

AZI280-01

Offers sensitive digital chemiluminescent detection at a low cost

Azure 280 digital chemiluminescent imager

The Azure 280 gives you the same sensitivity as chemiluminescent detection on film, but without the hassles of a darkroom and the expense of a bulky film developer.

GET PRICING TODAY

Azure 280™ | The Individual Lab Imager

The Individual Lab Imager

Chemi
Blue Light

White Light

Ultraviolet

Performance and Affordability Go Hand-in-hand

Quantitative Chemiluminescent Imaging

Just as sensitive as film, but easier and quantitative, the Azure 280 will revolutionize your chemiluminescent workflows and eliminate the need for a darkroom.

With the Azure 280, the software notifies you when bands are saturated and not suitable for quantitation. 

High-resolution Imaging

A 6.1MP camera provides high resolution imaging perfect for publications. Change the sample to optics distance using adjustable height shelf for enhanced detection. Zoom into the area of interest with ROI imaging to reduce background.

The same Western Blot was imaged on both x-ray film and the Azure Imaging System.
Figure 1. Saturation detection prevents errors in quantitation. The same Western Blot was imaged on both x-ray film and the Azure Imaging System. The Azure system detects when CCD saturation occurs and calculates an auto-exposure time to avoid saturated bands.
"Safe" Dye Detection

A less toxic alternative to ethidium bromide, less-harmful “Safe” dyes can be imaged with the EPI Blue LEDs standard in the Azure 280 and all other Azure Imaging Systems.

The same Western Blot was imaged on both x-ray film and the Azure Imaging System.
Figure 1. Saturation detection prevents errors in quantitation. The same Western Blot was imaged on both x-ray film and the Azure Imaging System. The Azure system detects when CCD saturation occurs and calculates an auto-exposure time to avoid saturated bands.
UV Imaging Ethidium Bromide
UV Imaging
Ethidium Bromide
Blue Light ImagingSYBR® Safe, SYBR® Gold, SYBR® Green
Blue Light Imaging. SYBR® Safe, SYBR® Gold, SYBR® Green. A less toxic alternative to ethidium bromide, less- harmful “Safe” dyes can be imaged with the EPI Blue LEDs standard in all the systems. Epi Blue is recommended as it delivers superior & uniform illumination with reduced background compared to transilluminated blue light.
Intuitive capture software controlled with a touchscreen

The Azure 280 provides high-resolution imaging ideal for publication purposes, as well as higher pixel well cap for higher dynamic range. It makes image acquisition as easy as placing your blot into the instrument and pressing a button—no more wasting time testing multiple film exposures to get the best image.

Dynamic Range of 4.82 orders of magnitude

4.8 OD Dynamic Range. Field of view: 20.4 x 16.6 cm

Peltier Cooling

Standard -50°C regulated cooling

Compact Design

At 42 x 56 x 33 cm, its small size translates into more room on your bench

Footprint of the Azure 600® Imager (38 cm x 55 cm x 36 cm; W x H x D) vs. the iBright® FL-1000 (dotted line; 38 cm x 60 cm x 68 cm; W x H x D)
Footprint of the Azure 600® Imager (38 cm x 55 cm x 36 cm; W x H x D) vs. the iBright® FL-1000 (dotted line; 38 cm x 60 cm x 68 cm; W x H x D)

Connectivity through Wi-Fi, Ethernet, and USB with Microsoft Windows 11 OS

One year ago (August 2021), we purchased an Azure 280 imaging system from Azure Biosystems. We wanted a low-cost yet high-performance and quantitative Western blot imaging system, and Azure 280 was exactly what we needed. The Azure 280 is easy to use and has identical capabilities as the Azure 300, but it is just not upgradeable. However, we were offered the option to upgrade in the future (if we wanted to) by trade-in. Nathan Hemendinger, the director of Eastern North America at Azure Biosystems was courteous and very accommodating.

Fadi Bou-Abdallah
Fadi Bou-Abdallah, Ph.D.
Professor of Chemistry, SUNY Potsdam
The Azure 280 Imaging System offers:

• Flexibility—High sensitivity and performance for chemiluminescent imaging

• Quantitative accuracy—Designed for quantitation, our reagents, imaging system, and software work seamlessly together to help you follow best practices for Western blot publication

• Intelligent workflow—Our user interface allows total customization over imaging protocols, while ensuring repeatability from sample to sample. Our systems feature Auto-Focus, Auto-Illumination and Filter Control, and Auto-Image Capture. An integrated touchscreen allows ease of use and it can easily be controlled by an external PC, if required.

• Data integrity—Azure Biosystems meets the standards for publication in all major journals, and additionally offers software to enable 21 CFR Part 11 Compliance.

Works Well with Your Favorite Applications

Azure 280 Specifications

ParameterAzure 280
Detection6.1 MP camera
Pixel resolution16-bit, 65,536, Grayscale
Peltier Cooling-50°C regulated cooling
7 Position Filter Wheel✓
Trans UV302 and 365nm✓
Color Imaging✓
Trans-white imaging✓
Chemiluminescence✓
Epi Blue Light Imaging✓
UV Safety Override Switch✓
Field of View20.4 x 16.6 cm
Unit dimensions (W x H x D)​42 x 56 x 33 cm / 16.5” x 22” x 13”
Weight​17.7 kg / 39 lbs
Power requirements100-240 VAC, 4A; Single Phase; Consumption: 0.4 kW (400 Watts)
SoftwareUnique touchscreen user interface for easy access to preset automatic applications
CertificationsCE, cTUVus

Compare Western Blot Imaging Systems

Choose the configuration that supports today’s studies, while maintaining the option to upgrade later on

Publications

Gut stem cell necroptosis by genome instability triggers bowel inflammation
Wang, Li, Wu et al
Nature (2020) 580 (7803), 386-390 DOI: 10.1038/s41586-020-2127-x
AI Summary: The Azure Biosystems c280 imager was used to capture images of Western blots, enabling the visualization and analysis of protein expression relevant to the study’s investigation of gut stem cell necroptosis in inflammatory bowel disease.
Snippet: Western blots. Cell lysates from isolated crypts were prepared as previously described 28 . Images were taken using an azure biosystems c280. Crypts were lysed by RIPA and then the insoluble fractions that remained were resuspended by RIPA solution of 6 M urea
The transcriptional repressor Fli1 inhibits proteostasis during nutrient stress to limit NK cell persistence in solid tumors
Ji, Armstrong, Li et al
Immunity (2026) 59 (3), 717-733.e10 DOI: 10.1016/j.immuni.2026.01.017
AI Summary: The Azure Biosystems Chemiluminescent Imaging System (c280) was used to image protein membranes, enabling the detection and analysis of protein expression changes that contributed to understanding NK cell dysfunction in the tumor microenvironment.
Snippet: aximum Sensitivity Substrate (Thermo Fisher, 34094). The membranes were imaged on an Azure Biosystems Chemiluminescent Imaging System (c280). RNA-seq library construction and s
Species-specific serine metabolism differentially controls natural killer cell functions
Li, Feng, Ball et al
Nat Metab (2025)
AI Summary: The Azure Biosystems c280 imager was used in this study to visualize protein bands during Western blot analysis, enabling quantification of protein expression relevant to understanding species-specific serine metabolism in natural killer cells.
Snippet: Proteins were detected with the SuperSignal West Pico PLUS ECL kit (Thermo Fisher) and visualized on an Azure Biosystems c280 imager. Band density was quantified
Adipose cDC1s contribute to obesity-associated inflammation through STING-dependent IL-12 production
Hildreth, Padilla, Gupta et al
Nat Metab (2023) 5 (12), 2237-2252 DOI: 10.1038/s42255-023-00934-4
AI Summary: The Azure Biosystems c280 imager was used to visualize and quantify protein band intensities, contributing to the analysis of protein expression levels in this study.
Snippet: Protein band intensities were detected using the SuperSignal West Pico PLUS ECL kit (Thermo Fisher), visualized on the Azure Biosystems c280 imager and quantified
MEF2C regulates NK cell effector functions through control of lipid metabolism
Li, Zhou, Lee et al
Nat Immunol (2024)
AI Summary: The Azure Biosystems c280 imager was used to visualize protein bands in western blot experiments, enabling quantification of protein expression levels critical to the study’s findings on MEF2C regulation of NK cell function.
Snippet: Proteins were detected with the SuperSignal West Pico PLUS ECL kit (Thermo Fisher) and visualized on an Azure Biosystems c280 imager. Band density was quantified
Showing 1-5 of 271 papers.
Powered by BizGenius

Downloads

Document TypeDescription
BrochureAzure Imager BrochureDOWNLOAD
BrochureAzure Imaging Systems Model ConfigurationsDOWNLOAD
User ManualAzure Imaging Systems User ManualDOWNLOAD

Headquarters:
Azure Biosystems, Inc.
6747 Sierra Court, Suite A-B
Dublin, CA 94568
United States

Tel: (925) 307 7127
Fax: (925) 905-1816
Info@azurebiosystems.com

Azure Biosystems Pte. Ltd.
68 Circular Road, #02-01
Singapore, 049422
北京艾杰蓝生物科技有限公司
北京市昌平区北七家镇定泗路北侧
雅安商厦C号二层1714

Copyright © 2026 Azure Biosystems Inc.
Shopping cart0
There are no products in the cart!
Continue shopping