Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Western Blot Imaging Systems

Azure Imaging Systems

High-performance Western blot imaging systems capable of NIR fluorescence, visible fluorescence, and chemiluminescence.

Application Driven Design for Ultimate Flexibility

Diverse Imaging Applications

Ready to expand your research past gels and membranes? What truly sets Azure Imaging Systems apart is their ability to image more than just blots, using cameras ranging from 5.4MP to 9.1MP.

From tissue sections and media plates to in vivo fluorescence of three-dimensional samples, the Azure Imaging Systems have unmatched depth-of-field that easily enables unparalleled imaging flexibility. Azure Imagers enable you to image 3D samples, such as mice and zebrafish.

Shown from left to right: Fluorescent protein in native gel, Mouse with RFP-expressing subcutaneous tumor, mouse brain tissue slides, three-color fluorescent Western blot, mice imaged RGB automatic mode, mouse brain slides, GFP/m-Cherry dish, GFP-expressing Arabidopsis thaliana

Direct, Mirror-free Detection

Azure Imagers deliver better performance through direct,-mirror-free detection. The sensor is placed close to the sample to maximize light collection efficiency and sensitivity.

The camera is strategically placed directly above the sample. Having the camera as close to the sample as possible makes way for the best light collection efficiency.

Graphic showing how light intensity is affected by the distance of a sample to its light source
Azure Imagers are designed for capturing maximum light output from the sample. The CCD sensor is placed close to the sample in order to maximize light collection efficiency, which also increases sensitivity.

Fluorescent Channel for Accurate Quantification

Solve the issue of housekeeping proteins, which lack linearity and normalization accuracy at high protein loads. Several Azure Imaging Systems can be upgraded with the Azure Q Module, an optional green fluorescence channel intended for detecting Total Protein Stains, such as TotalStainQ.

This can be used for efficient total protein normalization (TPN) of quantitative Western blots and helps achieve the most accurate quantification.

Quantitative Chemiluminescence

Just as sensitive as film, but easier and quantitative, the Azure Imaging Systems will revolutionize your chemiluminescent workflows and eliminate your need for a darkroom.

All of our models provide high-resolution imaging that’s perfect for publications. Change the sample to optics distance using adjustable height shelf for enhanced detection. Zoom into the area of interest with ROI imaging to reduce background.

Complete flexibility to control imaging, exposure time, and detection of color markers. The acquisition modes include preview, automatic and manual image capture, multiple and cumulative exposures

The same Western Blot was imaged on both x-ray film and the Azure Imaging System.
Saturation detection prevents errors in quantitation. The same Western Blot was imaged on both x-ray film and the Azure Imaging System. The Azure system detects when CCD saturation occurs and calculates an auto-exposure time to avoid saturated bands.

Visible Fluorescence

With high resolution, high sensitivity, low background fluorescence imaging, and up to 4 channel fluorescent detection from RGB to NIR spectrum, the Azure Imaging Systems enable quantitative Western Blotting and a whole lot more.

Full-color multiplex RGB LEDs and filters broaden your imaging capabilities to visible fluorescence wavelengths, increasing flexibility and expanding multiplexing options while keeping system-size compact and value high.

Choose the Azure 400 for visible fluorescence, the Azure 500 for NIR fluorescence, or the Azure 600 for both visible and NIR fluorescence.

Digital image of 3-color fluorescent multiplexed Western blot
Digital image of 3-color Western Blot using Azure Biosystems 600 imager. Lanes (from left to right) loaded with 1, 2, 5, 10, 20 μg HeLa cell lysate. Probed for tubulin (top), beta actin (middle) and GAPDH (bottom). The following settings were used: Light sources 6/7/4; Exposure time 1s/13s 204ms/677ms; Filter positions 6/7/4; Aperture 6400; Focus 5000/5250/5000; bin level 1x1.

Snapshot of Compatible Dyes

Multichannel, multimodal imagers, with near-infrared, visible light, and UV excitation channels.

Detect Cy dyes, Alexa dyes, Safe dyes, UV-activated stain for protein gels (tri-halo compound stain), and more*

*Other dyes are also possible depending in your Azure Imager configuration.

Applications

Azure Imaging Systems support multiple applications and are able to record data from fluorescent and chemiluminescent Western blots, bacterial plates, protein gels, nucleic acid gels, and more.

Resources

Document TypeDescription
BrochureAzure Imaging Systems BrochureDOWNLOAD
BrochureAzure Imaging Systems Model ConfigurationsDOWNLOAD
App NoteBrowse All Application NotesBROWSE

Request a Quote

Ready to visualize your data with unmatched accuracy trusted by thousands of users? Get pricing on an Azure Imager today.


Headquarters:
Azure Biosystems, Inc.
6747 Sierra Court, Suite A-B
Dublin, CA 94568
United States

Tel: (925) 307 7127
Fax: (925) 905-1816
Info@azurebiosystems.com

Azure Biosystems Pte. Ltd.
68 Circular Road, #02-01
Singapore, 049422

Copyright © 2026 Azure Biosystems Inc.
Shopping cart0
There are no products in the cart!
Continue shopping