The Sapphire FL and the Sapphire FL+ are both powerful imaging tools for molecular biology labs. Both instruments have capabilities for fluorescence imaging, phosphor imaging, and densitometry with chemiluminescence as an option. Both instruments have 24-bit detection with extended dynamic range, so a bright band and a faint one can appear on the same image without washing out the bright signal. Both instruments use the same exchangeable fluorescent laser and filter modules covering 375 to 900 nm wavelengths, and both module exchanges can be done in under two minutes.
So to decide which one is better for you, it matters what you plan to put on the glass.

Where they differ
Sample size. The Sapphire FL+ is built around a 46 x 25 cm scanning bed for large format samples, and it takes storage phosphor screens up to 20 x 40 cm. If you run large format gels, or you want to lay several blots down and scan them in a single pass, that is the reason the FL+ exists.
In vivo imaging. The Sapphire FL has five anesthesia ports for imaging living animals. That is the spec people skip past, and it is worth saying plainly: a bigger scanning bed does not substitute for it. If live animal imaging is part of your workflow, start with the Sapphire FL.
Sample height. The Sapphire FL provides 4 cm of clearance from lid to platen, which covers raised samples such as multiwell plates and petri dishes. The FL+ provides an increase to 5 cm of clearance. If your tallest sample is close to the FL clearance height, measure it before you decide.
Two questions that usually settle it
Do you image live small animals? If yes, the FL, and nothing else on the list outweighs that.
Do your gels or phosphor screens run large format? If yes, the FL+. This is the case where sample size physically decides it, and no workaround gets around a bed that is too small.
If neither question applies to your lab, you are choosing between two systems with the same optics, the same detection modes, and the same sensitivity, so the decision comes down to bench space and the sample sizes you expect to be running two or three years from now.
What you get either way
Whichever one you land on, the capability that tends to surprise people is phosphor imaging. Both the Sapphire FL and FL+ support phosphor imaging, making it possible to image radiolabeled samples without the need for traditional film development in a darkroom.
It also matters for quantitation. A recent paper from the Yang Gao lab at Rice University engineered a thermophilic Cas13a and reported a variant roughly 100 times more active than wild type in a collateral cleavage assay, with an EC50 of 36 pM. Claims like that are not something you see on a gel, they are something you measure: phosphor screen band intensities read across a concentration series spanning several orders of magnitude, then fitted. imaging on the FL and FL+ the FL andimaging has a dynamic range of 5.4 orders of magnitude.
Add fluorescence multiplexing, femtogram level sensitivity with common dyes, and a software controlled 7 mm focal plane that lets you merge scans taken at different depths, and both systems cover a wide spread of workflows from a single instrument.
Still deciding?
Let us know what you are imaging and we will tell you honestly which of the two fits. Sometimes the answer is the smaller one.