The potential applications of nano- or microrobots in medicine have long intrigued scientists who envision tiny robots delivering drugs, therapeutics, or even whole cells to specific targets, or carrying out delicate processes within the circulation such as breaking up clots or blockages. Targeted drug delivery could allow the use of compounds that are too toxic when administered systemically. To reach the promise of microrobots in these applications, the challenge of directing them where they need to go and/or actuating them only at the correct time and place must be overcome. This obstacle is especially tricky when the target location is deep within the tissue of an organism the size of a human being.
Various means of propelling microrobots are being studied, but magnetic propulsion presents advantages over chemical, light, or sound-based propulsion1. Magnetic fields can access deep physiological targets and rotating magnetic fields (RMFs) can help microrobots overcome barriers and penetrate tissue. Usually, microrobots distribute throughout the circulation after introduction to the body, so a means is needed to direct them to the intended area. In addition to delivering them to the correct target, optimizing the use of microrobots requires minimizing their actuation in non-target tissues.
Combining RMFs with magnetostatic selection fields
Recent work published in Nature Communications by Menghini et al describes a scheme to combine RMFs with magnetostatic selection fields to apply spatially selective torque density to microrobots and suppress off-target actuation with a goal of achieving the resolution and tissue depth required for in vivo applications2. First, the authors demonstrated the feasibility of their approach by applying spatially selective torque density to naturally magnetic bacteria in vitro. Then, they built a torque-focusing apparatus large enough to contain a mouse and demonstrated that focused actuation increased the accumulation of magnetic bacteria within tumors in a mouse model.

Validating a mouse-scale torque-focusing setup
The Sapphire Biomolecular Imager was used in assays to validate the mouse-scale torque-focusing setup. A mixing experiment was designed to demonstrate that the system could cause a magnet to spin only in the targeted region. A small (5 mm) cylindrical sample chamber was 3D printed and filled with glycerol, containing a small magnet at the bottom and red fluorescent nanoparticles at the top. Rotational actuation of the micromagnet would cause the magnet to spin and mix the fluorescent nanoparticles throughout the chamber, increasing the fluorescence (see attached figure). Fluorescence intensity was assessed with the Sapphire and quantified using AzureSpot software.
AzureSpot Pro is a powerful analysis software that combines several powerful analysis tools into one convenient and easy to use package. It is designed to guide you through the analysis process and makes complex and customized analysis simple. You can download a free trial here.
As shown in Figure 4, the mixing assay was used to show that fluorescence increased only when the torque was focused on the target, and not when the chamber was off target in any direction.
Results
This work demonstrates that it is possible to spatially restrict torque density by combining RMFs with magnetostatic selection fields, which could have potential application to developing microrobot approaches to human medicine.
More about system used in this study
Since the release of this publication, the first generation Sapphire used has been succeeded by the Sapphire FL, which was designed to be the flexible choice in bringing precise quantitation of nucleic acids and proteins. Learn more about this new imager.
The Sapphire FL is a fluorescent imaging system that includes phosphor imaging among its multiple available imaging applications. Its ability to phosphor image comes in handy especially for applications such as electrophoretic mobility shift assays (EMSA), enzyme assays, and in-vivo imaging. In addition to phosphor imaging, the Sapphire FL can carry out white light, multiplex fluorescence, bioluminescence, and chemiluminescence imaging of a wide variety of sample types, from membranes to slides to model organisms. Learn more about the Sapphire FL here.
Since this paper was published, the Sapphire has been succeed by the Sapphire FL
Designed for flexible choice in detection chemistry and samples, the Sapphire FL brings precise quantitation of nucleic acids and proteins

More research done with Sapphire
SOURCES
- Zhou H, Mayorga-Martinez CC, Pané S, Zhang L, Pumera M. Magnetically driven micro and nanorobots. Chem Rev. 2021;121(8):4999-5041.
- Mirkhani N, Christiansen MG, Gwisai T, Menghini S, Schuerle S. Spatially selective delivery of living magnetic microrobots through torque-focusing. Nat Comm. 2024;15(1):2160.