Western Blot vs. Immunoblot: Choosing the Right Tool for Your Analytical Goal

Categories
Electrophoresis Fluorescence imaging Imaging Immunoassay Protein Assays Quantification Uncategorized Western Blotting

In the modern molecular biology lab, the terms “Western blot” and “immunoblot” are often treated as synonyms. While both rely on the same fundamental principle—antibody-protein affinity—the workflows diverge significantly in the type of data they produce.

Choosing between a standard Western blot and a direct immunoblot (like a Dot Blot) isn’t just about terminology; it’s a strategic choice between high-throughput speed and molecular specificity.

Terminology: "What's in a Name?"

Technically speaking, Immunoblotting is the broad umbrella term that refers to any analytical technique that uses antibodies to detect specific proteins that have been immobilized on a membrane (typically nitrocellulose or PVDF).

A Western blot is a specific type of immunoblot. Named as a playful nod to the Southern blot (DNA) and Northern blot (RNA), the Western blot specifically requires an initial step of gel electrophoresis to separate proteins by size or charge before they are transferred to the membrane.

  • The Rule of Thumb: All Western blots are immunoblots, but not all immunoblots are Western blots (e.g., Dot blots or Slot blots skip the electrophoresis step).
The Core Difference: To Separate or Not to Separate?

The defining feature of a Western blot is the inclusion of gel electrophoresis. By separating proteins by size or charge before transferring them to a membrane, you gain a critical data point: the molecular weight of your target.

In contrast, immunoblotting is a broader category. Techniques like Dot blots or Slot blots involve applying a sample directly to the membrane. This skips the separation phase entirely, concentrating all proteins from the sample into a single spot.

Workflow Comparison
When to Choose a Direct Immunoblot (e.g., Dot Blot)

The direct immunoblot is the “speed-demon” of protein detection. Researchers typically choose this workflow when throughput is the priority over characterization.

  • Antibody Screening: When you have dozens of hybridoma clones and need to quickly identify which ones produce an antibody that recognizes your target, a dot blot is the most efficient filter.
  • Buffer and Condition Optimization: If you are testing a variety of blocking buffers or primary antibody concentrations, applying small “dots” of your sample allows you to test multiple variables on a single membrane in a fraction of the time.
  • Quick Checks: When you simply need to know if a protein is present (a “Yes/No” answer) and have already validated your antibody’s specificity, the direct detection of a dot blot can be ideal for its speed.
When a Western Blot is Non-Negotiable

Despite the extra steps (casting gels, running electrophoresis), the Western blot remains the gold standard for definitive protein analysis.

  • Verifying Specificity: Even the best antibodies can exhibit non-specific binding. The Western blot allows you to see if your antibody is binding to the correct molecular weight or if it’s picking up background “noise” or degradation products.
  • Studying Post-Translational Modifications: If you are investigating phosphorylation or glycosylation, the Western blot is essential. These modifications often cause a “shift” in molecular weight that can only be visualized through electrophoresis.
  • Differentiating Isoforms: When a gene produces multiple protein isoforms of different sizes, a direct immunoblot will only give you the total signal. A Western blot allows you to quantify each isoform individually.

Optimize Your Workflow with Azure Biosystems

Whether your research demands the rapid throughput of an immunoblot or the rigorous specificity of a Western blot, your results are only as good as your detection. Azure Biosystems provides imaging solutions engineered for high sensitivity and wide dynamic range to ensure your data is accurate every time.

Western blot detected with NIR immunodetection, using TotalStainQ
Conclusion

The choice between a Western blot and a direct immunoblot depends on where you are in your experimental timeline. If you are in the high-throughput screening phase, the speed of an immunoblot is an asset. However, for publication-quality data that confirms the identity and state of your target protein, the molecular weight confirmation of a Western blot is essential.

More posts on Immunoassays

SOURCES

  1. Towbin, H., et al. (1979). Electrophoretic transfer of proteins from polyacrylamide gels to nitrocellulose sheets. PNAS, 76(9), 4350–4354.
  2. Burnette, W. N. (1981). “Western blotting”: electrophoretic transfer of proteins from SDS-polyacrylamide gels. Analytical Biochemistry, 112(2), 195–203.
  3. Mahmood, T., & Yang, P. C. (2012). Western blot: technique, theory, and trouble shooting. North American Journal of Medical Sciences, 4(9), 429.

Bridging Binding and Biology: How CellarisBio Uses Azure Cielo to Unlock “Undruggable” Targets

Categories
qPCR Quantification Uncategorized

In the pursuit of modern drug discovery, the industry’s most significant challenges often lie with proteins that are structurally dynamic or elusive—the so-called “undruggable” targets like transcription factors and membrane proteins.

Today, we are highlighting how CellarisBio is tackling these challenges head-on. By leveraging the thermal precision of the Azure Cielo Real-Time PCR instrument, CellarisBio has developed MICRO-TAG®, a patented platform that is redefining how we study cellular target engagement.

The Science: Real-Time Cellular Target Engagement

MICRO-TAG® is built on a foundation of fluorescence enzyme complementation. The target protein is fused to a small peptide fragment of split RNase S; when the protein maintains its structural integrity inside the cell, the enzyme reconstitutes and generates a fluorescence signal.

However, the real breakthrough comes from how CellarisBio interrogates these proteins. Rather than looking at a single fixed condition, they use the Azure Cielo to apply programmable temperature gradients.

“By applying programmable temperature gradients in a real-time PCR instrument, we introduce controlled denaturing pressure and continuously monitor how ligand binding stabilizes or destabilizes the target,” explains Elmar Nurmemmedov, PhD, MBA, co-founder of CellarisBio.

Why the Azure Cielo?

The success of the MICRO-TAG® platform relies on the ability to deliver “continuous, programmable temperature-series profiling.” While traditional methods like CETSA often depend on a single aggregation point, the Cielo allows CellarisBio to capture a much richer data set.

The Cielo’s industry-leading thermal uniformity and high-performance optics enable CellarisBio to:

  • Interrogate Conformational Diversity: In a cellular environment, targets exist in multiple states. According to Dr. Nurmemmedov, the Cielo’s temperature series allows researchers to “quantify ligand engagement across a spectrum of structural states rather than at a single fixed condition.”
  • Capture Mechanistic Signatures: For dynamic targets that exist in open, closed, or partially folded states, this format produces “richer mechanistic signatures” than traditional luminescent systems.
  • Bridge the Gap: MICRO-TAG® serves as a vital link between biochemical affinity assays and functional cellular readouts. As Dr. Nurmemmedov puts it, the technology “bridges binding and biology by quantifying engagement directly in the cellular context.”
Redefining the Industry Landscape

The formal recognition of these high-throughput screening methods marks a shift in the industry. By moving beyond the limitations of traditional workflows, CellarisBio and the Azure Cielo are providing researchers with the tools needed to finally reach targets that were once considered out of reach.

For labs focused on complex multiprotein complexes and dynamic cellular environments, the combination of MICRO-TAG® and Azure Biosystems technology offers a clear path toward more effective drug discovery.

Ready to see the data?

Download the full Application Note, “Evaluation of CellarisBio MICRO-TAG® Cell Target Engagement Assay On Azure Cielo Real-Time PCR System.“ 

To discover more about CellarisBio’s MICRO-TAG® technology, visit CellarisBio.com

The Azure Cielo Advantage:
Powering Your Advanced Applications

The Azure Cielo Real-Time PCR System is built to support these advanced applications and more. Its rapid thermal cycling, exceptional thermal uniformity, and advanced optical system ensure the precision and reliability necessary for complex assays. With options for multiple detection channels, it offers the flexibility for powerful multiplexing, while its intuitive software simplifies data analysis for even the most intricate experiments.

Are You Using the Wrong qPCR Chemistry? Probes vs. Dyes Explained.

Categories
qPCR Quantification Uncategorized

Real-time PCR (qPCR) is the bedrock of molecular biology, offering precise measurement of nucleic acids. But before you hit ‘Run’ on your Azure Cielo Real-Time PCR System, you face a critical decision: should you use a fluorescent dye or a sequence-specific probe?

 

This choice dictates your experiment’s cost, complexity, and, most importantly, the specificity of your results.

The Case for Fluorescent Dyes (e.g., SYBR Green)

How Dyes Work:

Fluorescent dyes, such as SYBR Green, operate on a simple principle: they bind non-specifically to double-stranded DNA (dsDNA). Once bound, the dye fluoresces brightly.

When to Choose Dyes:

  • Initial Screening and Method Development: Dyes are excellent for quickly testing a large panel of primer pairs or optimizing new assays due to their low cost.
  • Cost-Effectiveness: Dyes are significantly cheaper than custom-synthesized probes, making them the default choice for large-scale, non-multiplexed experiments.
  • Target Flexibility: Since the dye binds any dsDNA, it’s considered a “universal” reagent. You only need to design primers, not a probe.

The Trade-Offs:

The primary drawback to fluorescent dyes is their lack of specificity. The dye will bind to the target product, but it will also bind to any non-specific product, like primer dimers. This can inflate your quantitative result (Ct value) and lead to inaccurate conclusions.

To mitigate this, you must always run a melt curve analysis. This post-amplification step monitors the dissociation of dsDNA products as the temperature increases, providing you with additional confidence that only the desired product was amplified.

The Power of Fluorescent Probes (e.g., TaqMan, Molecular Beacons)

Fluorescent probes offer a sequence-specific method of detection, providing a higher level of confidence in your results. The most common format is the hydrolysis probe (TaqMan), which uses a reporter fluorophore and a quencher molecule on opposite ends of a single oligonucleotide.

How Probes Work:

During amplification, the 5′ exonuclease activity of the Taq polymerase cleaves the probe only when it has hybridized specifically to the target sequence. This cleavage separates the reporter from the quencher, resulting in a dramatic increase in fluorescence signal.

When to Choose Probes:

  • High Specificity and Accuracy: Probes only signal when the exact target sequence is present and amplified. This makes them ideal for diagnostic assays or highly sensitive quantitative measurements.
  • Multiplexing: Because different targets can be labeled with probes carrying unique fluorophores (e.g., FAM, HEX, Cy5), you can detect multiple targets in a single reaction well. This conserves sample and time.
  • No Primer Dimer Interference: Since the signal depends only on the specific probe being cleaved, non-specific products like primer dimers do not generate a fluorescent signal, eliminating the need for a melt curve.

The Trade-Offs:

The main barrier to using fluorescent probes is cost. Probes require custom synthesis and must be designed perfectly for each target. The initial setup and per-reaction costs are significantly higher than those for dyes.

The use of fluorescent probes also requires the initial work of designing probes for each specific target as well as the experimental optimization of both the primers and probes.

Summary

The fundamental choice in qPCR chemistry boils down to a trade-off between cost and specificity. Fluorescent dyes, such as SYBR Green, are the more cost-effective option, ideal for initial screening and general expression analysis. However, their non-specific binding to all double-stranded DNA—including unwanted primer dimers—necessitates the use of a post-run melt curve analysis to validate results. Conversely, sequence-specific fluorescent probes (like TaqMan) offer vastly superior specificity and accuracy, as they only generate a signal after successful amplification of the exact target sequence. This makes probes essential for advanced applications such as multiplexing (detecting multiple targets in one reaction) and clinical diagnostics, despite their significantly higher cost due to the requirement for custom synthesis.

Ready to achieve superior qPCR results?

The Azure Cielo Real-Time PCR System is optimized for both dye-based and probe-based chemistries, delivering the thermal uniformity and broad spectral range needed for consistent, high-quality data.

More posts on q-PCR

SOURCES

  1. Bustin, S. A., et al. (2009). The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments. Clinical Chemistry, 55(4), 611-622.
  2. Kubista, M., et al. (2006). The real-time polymerase chain reaction. Molecular Aspects of Medicine, 27(2-3), 95-125.
  3. Holland, P. M., et al. (1991). Detection of specific polymerase chain reaction product by utiliing 5′—-3′ exonuclease activity of Thermus aquaticus DNA polymerase. Proceedings of the National Academy of Sciences, 88(16), 7276-7280.
  4. Ririe, K. M., et al. (1997). Product Differentiation by Analysis of DNA Melting Curves During the Polymerase Chain Reaction. Analytical Biochemistry, 245(2), 154-160.

Beyond the Basics: Advanced Applications for Your Real-Time PCR System

Categories
qPCR Quantification Uncategorized

Real-time PCR (qPCR) has long been an indispensable tool in the life sciences, widely celebrated for its speed, sensitivity, and quantitative precision in gene expression analysis. However, if you’re only using your real-time PCR system for basic gene quantification, you’re merely scratching the surface of its immense capabilities. Modern qPCR systems, like the Azure Cielo Real-Time PCR System, are designed to go far beyond simple Ct values, empowering researchers to tackle complex biological questions with advanced applications.

 

Let’s dive into some of the more sophisticated ways you can leverage your real-time PCR system to push the boundaries of your research.

1. KASP Genotyping: Robust and Scalable SNP Analysis

KASP (Kompetitive Allele Specific PCR) genotyping is a widely adopted, high-throughput, and cost-effective method for SNP (Single Nucleotide Polymorphism) and InDel (Insertion/Deletion) genotyping. It’s a fluorescence-based assay that uses two allele-specific forward primers and one common reverse primer.

How it works: Each allele-specific forward primer carries a unique tail sequence. The reaction also contains two universal probes, each specific to one of these tail sequences and labeled with a different fluorophore (typically FAM™ and HEX™). If an allele-specific primer successfully amplifies, its unique tail sequence is incorporated into the PCR product. This newly formed sequence then allows its corresponding universal probe to bind and be cleaved, leading to an increase in its specific fluorophore signal. By plotting the fluorescent signals from the two different fluorophores at the end of the reaction, genotypes can be clearly distinguished.

Why it’s useful:

  • High Throughput: Ideal for genotyping thousands of samples for one or more SNPs, or hundreds of samples for many SNPs.
  • Cost-Effective: Eliminates the need for expensive sequence-specific probes, making it a more economical choice for large-scale studies.
  • Biallelic Discrimination: Precisely discriminates between homozygous and heterozygous genotypes.
  • Robustness: Known for its reliability across various sample types and DNA qualities.
  • Wide Application: Used extensively in agriculture (crop and livestock breeding), human genetics, and population studies.

The multi-channel detection capabilities and the consistent thermal performance of real-time PCR systems like the Azure Cielo are perfectly suited for accurate KASP genotyping, allowing simultaneous monitoring of multiple fluorophores.

2. Pathogen Detection and Quantification (Multiplexed): Rapid and Comprehensive Pathogen Analysis

Real-time PCR has transformed infectious disease research and pathogen testing due to its speed and high sensitivity. Advanced applications often involve multiplexing – simultaneously detecting multiple pathogens or multiple targets from a single pathogen in a single reaction well.

Why it’s useful:

  • Syndromic Panels: Detect multiple respiratory or gastrointestinal pathogens from one sample, reducing turnaround time and increasing testing efficiency.
  • Antimicrobial Resistance (AMR) Gene Detection: Identify genes conferring resistance to antibiotics, guiding treatment decisions.
  • Viral Load Monitoring: Accurately quantify viral loads in patient samples for disease management and treatment efficacy assessment.
  • Specificity and Sensitivity: The ability to design highly specific primers and probes, combined with the instrument’s sensitivity, minimizes false positives and negatives.

A multi-channel real-time PCR system, like the 6-channel Azure Cielo is essential for these multiplexed assays, allowing simultaneous detection of multiple fluorescent probes.

3. miRNA and Non-Coding RNA Analysis: Exploring the Regulatory Landscape

MicroRNAs (miRNAs) and other non-coding RNAs are crucial regulators of gene expression, playing roles in various biological processes and diseases. Due to their small size and often low abundance, their quantification requires specialized qPCR chemistries and highly sensitive instrumentation.

Why it’s useful:

  • Biomarker Discovery: Quantify miRNA expression levels to identify potential biomarkers for disease research, prognosis, and therapeutic response.
  • Mechanistic Studies: Investigate the regulatory roles of miRNAs in cellular pathways.
  • Circulating miRNA Analysis: Detect and quantify miRNAs in bodily fluids (e.g., blood plasma) as non-invasive biomarkers.

The precision and sensitivity of modern real-time PCR systems like the Azure Cielo ensure accurate detection and quantification of these challenging targets.

Don’t let your real-time PCR system be limited to basic quantification. Explore the advanced applications and unleash its full potential to drive your discoveries forward.

The Azure Cielo Advantage:
Powering Your Advanced Applications

The Azure Cielo Real-Time PCR System is built to support these advanced applications and more. Its rapid thermal cycling, exceptional thermal uniformity, and advanced optical system ensure the precision and reliability necessary for complex assays. With options for multiple detection channels, it offers the flexibility for powerful multiplexing, while its intuitive software simplifies data analysis for even the most intricate experiments.

More posts on q-PCR

SOURCES

  1. Bustin, S. A., et al. (2009). The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments. Clinical Chemistry, 55(4), 611-622.
  2. Eisenberg, E., & Levanon, E. Y. (2013). Human housekeeping genes, revisited. Trends in Genetics, 29(10), 569-574.
  3. D’Souza, L. J., et al. (2017). Housekeeping genes in gene expression studies. Journal of Applied & Translational Genomics, 6(1).
  4. Vandesompele, J., et al. (2002). Accurate normalization of real-time quantitative RT-PCR data by geometric averaging of multiple internal control genes. Genome Biology, 3(7), research0034.
  5. Kubista, M., et al. (2006). The real-time polymerase chain reaction. Molecular Aspects of Medicine, 27(2-3), 95-125.

The Key to Consistent Western Blots: TotalStain Q for Reliable Data

Categories
Fluorescence imaging Imaging In-cell Western Protein Assays Quantification Uncategorized Western Blotting
Western Normalization

For decades, normalizing Western blot data to housekeeping proteins like β-actin or GAPDH has been a common practice, with the underlying assumption that their expression across experimental conditions would remain stable. However, a growing body of evidence challenges this assumption and sheds light on the inherent variability of these controls [1, 2]. This variability can lead to inaccurate interpretations of critical data. A more robust and increasingly recognized approach is total protein staining, which offers a global assessment of protein loading. 

The Downside of Housekeeping Proteins

Studies have demonstrated that the expression of common loading controls can be significantly affected by various factors, including:

  • Experimental treatments: Drug treatments, hypoxia, and other interventions can alter the expression of β-actin and GAPDH [3].
  • Cell type and tissue specificity: Expression levels can vary dramatically between different cell lines and tissues [4].
  • Developmental stage and differentiation: Housekeeping protein expression often changes during cellular development and differentiation processes [5].
  • Subcellular localization: The abundance of a housekeeping protein in a specific cellular compartment might not reflect the overall protein levels.

Relying on the potentially variable expression of a single protein for normalization introduces a significant risk: normalizing your target protein to a variable denominator can potentially mask or exaggerate true biological effects.

Total Protein Staining: A More Reliable Option

Total protein staining offers a powerful alternative by providing a direct measure of the total protein loaded in each lane. This approach offers several key advantages:

  • Direct Measurement of Loading: The amount of protein transferred to the membrane is directly quantified, accounting for pipetting errors and variations in sample preparation.
  • Normalization to the Entire Proteome: By normalizing to the total protein, you are essentially using the entire protein population as your reference, mitigating the impact of fluctuations in individual proteins.
  • Visual Confirmation of Transfer Efficiency: Before committing to antibody incubations, total protein stains allow for a quick and easy assessment of whether proteins have transferred uniformly across the membrane, ensuring the integrity of subsequent analysis.
  • Increased Data Reliability: Studies have shown that total protein normalization can provide more accurate and reliable results compared to single housekeeping protein normalization, especially in complex experimental settings [5].
TotalStain Q: Revolutionizing the Way You Western Blot

Azure TotalStain Q is a reversible, ready-to-use total protein stain specifically designed to enhance your Western blot workflow. It offers a unique combination of features that streamline your process and improve the quality of your data:

1. Rapid Transfer Verification

Azure TotalStain Q allows for rapid visualization of transferred proteins on your membrane. This crucial step, performed before antibody incubation, enables you to:

  • Identify transfer inconsistencies: Detect uneven transfer, air bubbles, or membrane contact issues that could skew your results.
  • Ensure equal protein representation: Confirm that proteins across the entire molecular weight range have transferred efficiently and uniformly in all lanes.
  • Save valuable time and resources: By identifying transfer problems early, you can avoid wasting antibodies and reagents on flawed blots.
2. Sensitive and Linear Total Protein Detection

Following transfer verification, Azure TotalStain Q provides a highly sensitive and linear stain for the accurate quantification of total protein in each lane. This allows for:

  • Precise normalization: Normalize your target protein signal to the total protein loaded, providing more accurate quantification of your target protein.
  • Detection of subtle changes: By accounting for loading variations across the entire proteome, you can more confidently identify subtle but significant changes in your protein of interest.
  • Compatibility with downstream analysis: The reversible nature of TotalStain Q ensures it can be easily removed without interfering with subsequent antibody binding and detection, including fluorescent Western blotting.
A comparison of protein normalization strategies.

Stop Guessing!

Request a FREE sample of Azure TotalStain Q, the reversible and highly sensitive total protein stain that not only ensures uniform protein transfer for accurate results but also provides reliable normalization. Experience the difference in your data with more consistent quantification and the confidence that your Western blots truly reflect your samples.

Western blot detected with NIR immunodetection, using TotalStainQ
Conclusion

While housekeeping proteins have historically served as normalization tools in Western blotting, the growing recognition of their inherent variability necessitates a more robust approach. Total protein staining, particularly with innovative solutions like Azure TotalStain Q, offers a significant advantage by providing a direct measure of protein loading and transfer efficiency. By incorporating TotalStain Q into your Western blot workflow, you can enhance the reliability and accuracy of your data, leading to more confident and impactful research findings.

Read about how others are using  TotalStain Q in their research:

Recent publications utilizing the power of TotalStain Q

More posts on Total Protein Normalization

SOURCES

  1. Radonic, A., Thulke, S., Mackay, I. M., Landt, O., Siegert, W., Nitsche, A., & Pfaffl, M. W. (2004). Guideline to reference gene selection for quantitative real-time PCR. Biotechniques, 37(4), 601-606.
  2. Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., … & Wittwer, C. T. (2009). The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments. 1 Clinical chemistry, 55(4), 2 611-622.  
  3. Kinnally, K. W., Zorov, D. B., Antonenko, Y. N., & Saks, V. A. (2007). Mitochondrial creatine kinase in cardiac function. Journal of molecular and cellular cardiology, 42(6), 1055-1067.
  4. Ditton, A. S., Esposito, E., McLellan, G. J., Nash, G. B., & Wilkins, R. J. (2010). Housekeeping proteins as internal standards: are they reliable in normal and stressed cells?. Journal of cellular physiology, 225(1), 17-21.
  5. Aldridge, K., Hossain, M., & Tan, A. M. (2008). Beta-actin and GAPDH are not reliable loading controls for Western blot analysis of protein expression in MCF-7 cells. Journal of proteome research, 7(12), 5198-5200.

Sapphire Biomolecular Imager Used for IC50 Determination Using In-Cell Western in Recent Publication

Categories
Fluorescence imaging Imaging In-cell Western Protein Assays Publication Spotlight Quantification Uncategorized Western Blotting
Publication Spotlight: Using the Sapphire Biomolecular Imager to Research Protective Nanobodies

Though the World Health Organization declared the end of the COVID-19 Public Health Emergency in 2023, the SARS-CoV2 virus is far from eradicated. In fact, recent outbreaks of new Omicron subvariants have caused surges in COVID hospitalizations globally, and evidence has shown some of these subvariants to evade antibody immunity in vaccinated and/or infected individuals. Next generation antibodies and vaccines are needed to combat the threat of these subvariants and other sarbecoviruses such as SARS-CoV-1.

 

In a recent publication in PLOS Pathogens, Dong et al report on their identification of a set of nanobodies with extremely broad and potent neutralizing activity against diverse human and animal sarbecoviruses, including the recently emerged Omicron subvariants, SARS-CoV-1 and coronaviruses from bats and pangolins. The best among the identified nanobodies has demonstrated robust protection in Syrian hamsters against contact and respiratory transmission of Omicron subvariants and is a promising candidate for blocking the transmission of various sarbecoviruses.

Neutralization breadth and potency of top 5 nanobodies against 25 diverse sarbecoviruses.
Neutralization breadth and potency of top 5 nanobodies against 25 diverse sarbecoviruses.
Using the Sapphire Biomolecular Imager to Determine IC50

Dong et al isolated positively reacting nanobodies through iterative MACS-sorting, FACS-sorting, and enrichment. The neutralizing activity of the top five nanobodies was tested by determining the IC50 of the nanobodies using the Sapphire Biomolecular Imager. A focus reduction neutralization test (FRNT) was performed using serial dilutions of the top nanobody candidates mixed and incubated with authentic SARS-CoV-2. The mixtures were added to cultured cells and incubated for 24 hours before the neutralizing effects of the nanobody were detected. The fluorescence density of the SARS-CoV-2 infected cells was scanned using the Sapphire Biomolecular Imager and the IC50 was quantified based on the 50% reduction in fluorescence.

Neutralizing activity of five mutants of the top nanobody candidate.
a. Neutralizing activity (IC50 and IC90) of five Tnb04-1 mutants against a panel of diverse pseudoviruses. b. Neutralization curves of the five Tnb04-1 mutants, from which IC50 and IC90 are estimated. c. Binding kinetics of the five Tnb04-1 mutants compared to the wildtype Tnb04-1. d and e. Comparisons of Tnb04-1 and Tnb03 paratope and epitope residues.
More about the Imager used in this study

The Sapphire FL is a fluorescent imaging system built for flexibility. With customizable and user-changeable laser and filter modules, 5–1000 μm resolution scans, and a Z-plane range from -1.0 to +6 mm, the Sapphire FL can easily adapt to your lab’s changing research needs. In addition to multiplex fluorescence, the Sapphire FL can carry out phosphor imaging, bioluminescence, and chemiluminescence imaging of a wide variety of sample types, from membranes to slides to model organisms.

scientist opening the lid of a sapphire FL
Conclusion

This work from Dong et al showed nanobodies with remarkable neutralizing activity to newly emerged and highly divergent Omicron subvariants as well as certain coronaviruses. These are promising candidates for disrupting the cycle of immune selection and viral escape through effectively blocking respiratory acquisition and transmission of diverse sarbecoviruses. Further study may provide potential ways to utilize these nanobodies and antibodies as effective protection against circulating and future variants.

More posts on IC50 and In-cell Western Blotting

In-cell Western Assays for IC50 Determination

Categories
Fluorescence imaging Imaging In-cell Western Protein Assays Quantification Uncategorized Western Blotting
Understanding IC50

Half maximal inhibitory concentration, also known as Inhibitory Concentration 50 or IC50, is an important metric in pharmacology and drug discovery. It quantifies the concentration of a compound required to inhibit a specific biological process by 50%. Traditionally, methods like ELISA and flow cytometry have been used to determine IC50 values. However, in recent years, in-cell Westerns have emerged as a powerful tool for this purpose.

In-cell Western used to determine IC50 of a compound
Why In-Cell Western for IC50 Analysis?

In-cell Westerns combine the principles of immunoassays and Western blotting to directly assess protein expression and phosphorylation within intact cells. This technique offers several advantages for IC50 analysis:

  • Physiological Relevance: Traditional Westerns require cell lysis, extracting proteins from the cellular environment for analysis. In-cell Westerns, on the other hand, assess protein expression and phosphorylation within cells, providing a more accurate representation of drug effects in a cellular context.
  • High-Throughput Screening: This technique is well-suited for high-throughput screening, enabling the rapid testing of large numbers of compounds and conditions.
  • Quantitative Analysis: In-cell Westerns offer quantitative data on protein expression and phosphorylation levels, which allows for accurate IC50 determination. This quantitative data can also be used to compare the potency of different compounds to optimize drug design.
  • Multiplex Analysis: In-cell Westerns allow for the simultaneous analysis of multiple proteins in the same sample. This can provide valuable insights into the mechanisms of action of compounds and identify potential off-target effects.
Graph comparing the IC50 data of four different experimental conditions
Example of IC50 data plot.
Typical In-Cell Western Workflow for IC50 Analysis
  1. Cell Culture and Treatment: Cells are cultured and treated with increasing concentrations of a compound or condition of interest.
  2. Cell Fixation and Permeabilization: Cells are fixed to preserve protein expression and phosphorylation then permeabilized to allow detection reagents within the cells.
  3. Western: Cells are incubated with primary antibodies specific to the target protein(s) and secondary antibodies conjugated to a fluorescent label such as AzureSpectra.
  4. Image Acquisition: The cells are imaged using an imaging system, such as the Sapphire FL Biomolecular Imager.
  5. Data Analysis: The intensity of the signal from the target protein is quantified using image analysis software such as AzureSpot Pro. The resulting data can be used to determine the IC50 value using nonlinear regression analysis. 

Need More Help Using In-Cell Westerns for IC50?

Azure's IC50 Workbook gives instructions on how to set up your assay and walks you through the steps of data analysis from signal acquisition to IC50 determination.
scientist opening the lid of a sapphire FL
Conclusion

In-cell Westerns are a powerful and versatile approach for IC50 determination. By providing a physiologically relevant and quantitative assessment of drug effects, in-cell Westerns have become an indispensable tool in drug discovery and development. The power of in-cell Westerns allows researchers to accelerate the identification of novel therapeutic agents and advance our understanding of disease mechanisms.

More posts on In-cell Western Blotting

SOURCES

  1. Zlokarnik, G. The in-cell Western: a robust high-throughput imaging approach for functional genomics. Current Opinion in Chemical Biology 8.1 (2004): 31-37.
  2. Lam, F., et al. In-cell Western analysis: a high-throughput platform for cell biology. Nature Methods 5.4 (2008): 307-315.

Handy Resources to Improve Western Blots

Categories
Troubleshooting Western Blotting

At Azure Biosystems we live and breathe all things Western blotting. From innovative imagers, to top notch reagents and accessories, to customer education, we are here to support you in your quest for the most robust Western blotting protocols, techniques and data no matter where you are in your Western blotting career.

Are you a Western blotting novice trying to learn more about the process to perfect your technique? Or maybe you’re a veteran Western blotter looking to improve your blots or switch detection methods. In either case, bookmark this page to use as a list of Western blotting resources and troubleshooting. Check out the handy infographic below to see which reagents you may need to get started on your Western blot.

Western blotting steps with reagents listed
Figure 1. List of comprehensive Western blotting steps with reagents listed

Helpful resources to IMPROVE your Western blotting game:

FREE WESTERN BLOT eBOOK

New to Western blotting? Need to troubleshoot your Western blot?​ Want to brush up on Western blotting best practices? Claim your free Western Blotting eBook!

WATCH: Troubleshooting Common Issues with Western Blotting